67 research outputs found

    Comparative Analysis of the Visual, Refractive and Aberrometric Outcome with the Use of 2 Intraocular Refractive Segment Multifocal Lenses

    Get PDF
    To demonstrate the results of ray tracing higher- and lower-order aberrations in pseudophakic eyes with rotationally asymmetrical segment multifocal lenses, total high- and low-order aberrations, measured by root mean square value (RMS), refraction, uncorrected distance and uncorrected near visual acuity (UCDVA and UCNVA), and tear break-up time, were measured at scotopic size in 42 eyes of patients implanted with bifocal refractive Mplus15/Mplus30 IOL with +1.5 dpt near addition (42 eyes of patients implanted with Mplus15)/+3.0 dpt near addition (91 eyes of patients implanted with Mplus30), and 107 eyes of control group. No significant differences were noticed between the examined groups concerning UCDVA, UCNVA, and tear break-up time (p < 0.001). Coma and total high-order aberrations were significantly higher for the Mplus30 lens in comparison to the Mplus15 lens and the control group (Coma, Trefoil p < 0.001, Secondary Astigmatism p = 0.002). The spherical aberrations were significantly higher in the lower-addition lens (p = 0.016) in comparison to the control group and to the higher-addition lens group (p < 0.001). Both intraocular lens models were successful at reaching refractive aim, good distance, and near function with the lower higher-order aberrations for the low-addition lens

    Hydrogel membranes based on genipin-cross-linked chitosan blends for corneal epithelium tissue engineering

    Get PDF
    Novel polymeric hydrogel scaffolds for corneal epithelium cell culturing based on blends of chitosan with some other biopolymers such as hydroxypropylcellulose, collagen and elastin crosslinked with genipin, a natural substance, were prepared. Physicochemical and biomechanical properties of these materials were determined. The in vitro cell culture experiments with corneal epithelium cells have indicated that a membrane prepared from chitosan–collagen blend (Ch–Col) provided the regular stratified growth of the epithelium cells, good surface covering and increased number of the cell layers. Ch–Col membranes are therefore the most promising material among those studied. The performance of Ch–Col membranes is comparable with that of the amniotic membrane which is currently recommended for clinical applications

    NMR Spectroscopy of Human Eye Tissues: A New Insight into Ocular Biochemistry

    Get PDF
    Background. The human eye is a complex organ whose anatomy and functions has been described very well to date. Unfortunately, the knowledge of the biochemistry and metabolic properties of eye tissues varies. Our objective was to reveal the biochemical differences between main tissue components of human eyes. Methods. Corneas, irises, ciliary bodies, lenses, and retinas were obtained from cadaver globes 0-1/2 hours postmortem of 6 male donors (age: 44–61 years). The metabolic profile of tissues was investigated with HR MAS 1H NMR spectroscopy. Results. A total of 29 metabolites were assigned in the NMR spectra of the eye tissues. Significant differences between tissues were revealed in contents of the most distant eye-tissues, while irises and ciliary bodies showed minimal biochemical differences. ATP, acetate, choline, glutamate, lactate, myoinositol, and taurine were identified as the primary biochemical compounds responsible for differentiation of the eye tissues. Conclusions. In this study we showed for the first time the results of the analysis of the main human eye tissues with NMR spectroscopy. The biochemical contents of the selected tissues seemed to correspond to their primary anatomical and functional attributes, the way of the delivery of the nutrients, and the location of the tissues in the eye

    Atypical regressive corneal endothelial cysts in long-term confocal follow-up

    Get PDF
    Corneal endothelium is formed of 1 layer of mitochondria-rich cubic cells whose main role is to maintain corneal transparency. Corneal endothelial disorders represent group of both inherited and noninherited and may affect proper vision. A 36-year-old male patient with suspicion of corneal endothelial dystrophy underwent visual acuity, intraocular pressure, the basic slit-lamp examination, anterior segment optical coherence tomography (AS-OCT) (Visante, Carl Zeiss Meditec, Dublin, CA), and corneal confocal microscopy in vivo (Rostock Cornea Module, Heidelberg Engineering Retina Tomograph III, Heidelberg, Germany). During the 3-year observation the patient reported symptoms mainly in the right eye. Slit-lamp examination revealed endothelial changes, much more pronounced in the right eye. Examination by the AS-OCT Visante showed hyperreflective dots within the right corneal endothelium. In order to assess endothelial cell morphology, analysis using corneal confocal microscopy in vivo was performed. Scans revealed presence of single endothelial deposits and severe cell changes of different morphology in both eyes. In the right eye, less pronounced changes of the polymorphic structure-polygonal guttas in different stages, linear and branched loss with "nuclear-like" formations and accompanying sediments. In the left eye, severe homomorphous polygonal "guttas-like" changes with "nuclear-like" formations were observed. Endothelial cysts' features were dynamically changing during follow-up time with different effects on the patient's clinical state. Corneal confocal microscopy allows accurate imaging of the endothelial cells and their detailed characteristics. Structural changes within the endothelial cells are not always proportional to visual acuity and slit-lamp image. The presented case is an example of an unusual corneal endothelial syndrome with probably nondystrophic background due to observed dynamic state with regressive tendency

    Automatic analysis of selected choroidal diseases in OCT images of the eye fundus

    Get PDF
    Introduction: This paper describes a method for automatic analysis of the choroid in OCT images of the eye fundus in ophthalmology. The problem of vascular lesions occurs e.g. in a large population of patients having diabetes or macular degeneration. Their correct diagnosis and quantitative assessment of the treatment progress are a critical part of the eye fundus diagnosis.Material and method: The study analysed about 1'000 OCT images acquired using SOCT Copernicus (Optopol Tech. SA, Zawiercie, Poland). The proposed algorithm for image analysis enabled to analyse the texture of the choroid portion located beneath the RPE (Retinal Pigment Epithelium) layer. The analysis was performed using the profiled algorithm based on morphological analysis and texture analysis and a classifier in the form of decision trees.Results: The location of the centres of gravity of individual objects present in the image beneath the RPE layer proved to be important in the evaluation of different types of images. In addition, the value of the standard deviation and the number of objects in a scene were equally important. These features enabled classification of three different forms of the choroid that were related to retinal pathology: diabetic edema (the classification gave accuracy ACC1 = 0.73), ischemia of the inner retinal layers (ACC2 = 0.83) and scarring fibro vascular tissue (ACC3 = 0.69). For the cut decision tree the results were as follows: ACC1 = 0.76, ACC2 = 0.81, ACC3 = 0.68.Conclusions: The created decision tree enabled to obtain satisfactory results of the classification of three types of choroidal imaging. In addition, it was shown that for the assumed characteristics and the developed classifier, the location of B-scan does not significantly affect the results. The image analysis method for texture analysis presented in the paper confirmed its usefulness in choroid imaging. Currently the application is further studied in the Clinical Department of Ophthalmology in the District Railway Hospital in Katowice, Medical University of Silesia, Poland

    Methods of measuring the iridocorneal angle in tomographic images of the anterior segment of the eye

    Get PDF
    Introduction: This paper presents the problem of automatic measurement of the iridocorneal angle in tomographic images of the anterior segment of the eye. It includes the results of the comparison of well-known methods for measuring the iridocorneal angle with new methods, proposed in this paper. All these methods concern tomographic image analysis and processing.Material and method: In total, approximately 100'000 tomographic images (from about 6'000 patients) were analysed. They were obtained using two devices: SOCT Copernicus (Optopol Tech. SA, Zawiercie, Poland) and Visante OCT (Carl Zeiss Meditec, Inc, Dublin, California, USA). The patients, aged 12 to 78 years with varying degrees of the iridocorneal angle pathology, were from the region of Silesia, Poland. The images were in DICOM or RAW formats and analysed in the software developed by the authors for the purposes of this study.Results: The results indicate that the measurement method proposed by the authors, which is based on the calculation of the minimum distance between the iris and the cornea in the adopted area, is the most accurate. For this method sensitivity was 0.88, specificity 0.89 and the area under the Receiver Operating Characteristic curve (AUC) was 0.88. The other known methods for measuring the iridocorneal angle gave worse results, that is, for example, for the measurement of the distance between the iris and the cornea AUC = 0.87, sensitivity = 0.86 and specificity = 0.71. For another well-known method of measuring the iridocorneal angle AUC = 0.77, sensitivity = 0.82 and specificity = 0.61.Conclusions: The study proved that the proposed method of measuring the minimum distance between the iris and the cornea within the adopted area is the most effective in the classification of the iridocorneal angle in patients with a high degree of pathology of all the compared measurement methods based on tomographic images. However, it requires fully automated measurement

    Long-term outcomes of allogeneic ocular surface reconstruction : keratolimbal allograft (KLAL) followed by penetrating keratoplasty (PK)

    Get PDF
    Purpose. Long-term results of the patients with total LSCD, who had undergone keratolimbal allograft (KLAL) for limbal reconstruction followed by penetrating keratoplasty (PK). Methods. +e study analyzes surgical treatment of 43 eyes with severe ocular surface disorders. All subjects underwent KLAL to achieve suitable conditions for consecutive PK. Due to failures of primary treatment in 17 eyes (39%), the KLAL was repeated. PK was performed in all the patients at 9-12 months after KLAL. As a retrospective study we analyzed data from the medical records including the preoperative and postoperative best corrected visual acuity, corneal clarity, surgical outcomes and complications, postoperative intraocular pressure, graft rejection, and other comorbidities and complications. Results. +e preoperative visual acuity ranged from light perception to 0.01. +e final improvement of visual acuity within a gain of one or more lines with the Snellen chart, including the results of successive surgical treatments after PK, was achieved in 23 operated eyes (53%). Early graft rejection was observed in 4 eyes (9%). In 3 eyes, it was manifested as endothelial rejection, and in 1 eye, as combined endothelial and epithelial rejection. PK failure requiring repetitive PK was present in 14 eyes (32%). Phthisis bulbi developed in 6 eyes (14%). Glaucoma or ocular hypertension was reported in 25 eyes (58%). A majority were treated with up to 3 topical agents or referred for trabeculectomy in 3 cases, transscleral cyclophotocoagulation in 2 eyes, and EX-PRESS glaucoma shunt implantation in 3 cases. Conclusions. Successful KLAL carries a high risk of subsequent PK failure. Visual function remains the second aim of treatment; the primary one is to stabilize the surface

    Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus

    Get PDF
    Background: The available scientific literature contains descriptions of manual, semi-automated and automated methods for analysing angiographic images. The presented algorithms segment vessels calculating their tortuosity or number in a given area. We describe a statistical analysis of the inclination of the vessels in the fundus as related to their distance from the center of the optic disc.Methods: The paper presents an automated method for analysing vessels which are found in angiographic images of the eye using a Matlab implemented algorithm. It performs filtration and convolution operations with suggested masks. The result is an image containing information on the location of vessels and their inclination angle in relation to the center of the optic disc. This is a new approach to the analysis of vessels whose usefulness has been confirmed in the diagnosis of hypertension.Results: The proposed algorithm analyzed and processed the images of the eye fundus using a classifier in the form of decision trees. It enabled the proper classification of healthy patients and those with hypertension. The result is a very good separation of healthy subjects from the hypertensive ones: sensitivity - 83%, specificity - 100%, accuracy - 96%. This confirms a practical usefulness of the proposed method.Conclusions: This paper presents an algorithm for the automatic analysis of morphological parameters of the fundus vessels. Such an analysis is performed during fluorescein angiography of the eye. The presented algorithm automatically calculates the global statistical features connected with both tortuosity of vessels and their total area or their number

    Metabolomic Signature Discriminates Normal Human Cornea from Keratoconus - A Pilot GC/MS Study

    Get PDF
    The molecular etiology of keratoconus (KC), a pathological condition of the human cornea, remains unclear. The aim of this work was to perform profiling of metabolites and identification of features discriminating this pathology from the normal cornea. The combination of gas chromatography and mass spectrometry (GC/MS) techniques has been applied for profiling and identification of metabolites in corneal buttons from 6 healthy controls and 7 KC patients. An untargeted GC/MS-based approach allowed the detection of 377 compounds, including 46 identified unique metabolites, whose levels enabled the separation of compared groups of samples in unsupervised hierarchical cluster analysis. There were 13 identified metabolites whose levels di erentiated between groups of samples. Downregulation of several carboxylic acids, fatty acids, and steroids was observed in KC when compared to the normal cornea. Metabolic pathways associated with compounds that discriminated both groups were involved in energy production, lipid metabolism, and amino acid metabolism. An observed signature may reflect cellular processes involved in the development of KC pathology, including oxidative stress and inflammation
    corecore